How we estimate your solar generation

The short version. We use 19 years of weather data for your district, allow for your roof, subtract realistic losses, and take the lower of two independent sources for every month. Your savings are calculated from that conservative figure.

1. Sunlight for your district. PVGIS 5.3, a free public tool from the European Commission, with its ERA5 weather data for 2005–2023, gives the expected panel output at each district headquarters for every month.

2. Your roof. A flat RCC roof gets a stand tilted towards the south at the best angle for your district. A tin or tiled roof keeps the panels flat on the slope, so its direction matters. Heat, which lowers output in summer, and hills on the horizon are included.

3. Realistic losses. We subtract 14% for wiring, the inverter and dust on the panels.

4. A second opinion. Weather-model data tends to over-estimate sunshine in hazy winter months, so we compare every month with NASA POWER and use whichever is lower.

What this data can and cannot tell you

It is reliable for:

  • How output rises and falls through the year, including the monsoon dip
  • How much a roof's direction and angle change output
  • How much one year can differ from another
  • Differences between districts

It cannot tell you:

  • Shade from a water tank, stair room, tree or a neighbour's building. We check this on the free site visit.
  • Exactly what your system will produce. It is an estimate from weather data, not a reading from your roof, and not a promise.

A study comparing this weather data with 27 India Meteorological Department stations found it close to ground readings on average, with a slight under-estimate in the monsoon. Where it is weakest — hazy winters — our second-source rule applies.

Glossary

Solar terms, explained

The words you will see in your estimate, in plain language.

What does kW (or kWp) mean?↓
The size of a solar system. "kWp" means kilowatt-peak: the rated power of the panels in standard lab conditions. A 3 kW system is about six 550 W panels.
What is a unit (kWh)?↓
One unit on your JBVNL bill. A 1 kW appliance running for one hour uses one unit.
What is solar irradiation?↓
How much sunlight energy reaches the ground over a period, per square metre. More irradiation means more units from the same panels.
What is GHI?↓
Global Horizontal Irradiation: all the sunlight falling on flat ground, both direct sun and light scattered by sky and clouds.
Why does the tilt of the panels matter?↓
Panels facing the sun more squarely catch more light. Across Jharkhand, about 28–31° towards the south gives the most over a year, which is why flat roofs get a tilted stand.
Why does the direction of my roof matter?↓
The sun sits in the southern half of the sky here, so south-facing panels produce the most. East- and west-facing roofs still work but produce less; north-facing produce the least. The explorer on this page shows how much.
What is specific yield?↓
Units produced per year for each 1 kW installed. It lets you compare places and roofs fairly, whatever the system size.
What are system losses?↓
Energy lost between the panels and your meter: dust, wiring, the inverter and small mismatches between panels. We assume 14%. Heat losses are calculated separately, month by month.
Why is May not the best month if it is so sunny?↓
Panels lose output when they are hot. In May the extra heat cancels part of the extra sunshine.
What is reanalysis (ERA5) data?↓
A reconstruction of past weather made by combining millions of real observations — weather stations, weather balloons, ships and aircraft — with a weather model, on a grid about 30 km wide. It is reliable for monthly and seasonal patterns, but it is not a reading from your roof.
What is PVGIS?↓
The Photovoltaic Geographical Information System: a free, public tool from the European Commission’s Joint Research Centre that turns weather data into expected solar output for any location.
What is NASA POWER?↓
A free NASA dataset of long-term sunlight averages. We use it as an independent second opinion on PVGIS.
What does "conservative estimate" mean here?↓
For each month we compare PVGIS with NASA POWER and use the lower of the two. The most common error in weather-model data for our region is over-estimating sunshine in hazy winter months; this rule protects you from it.
What does the lighter band on the chart show?↓
Year-to-year variation. Some years are cloudier than others. The band runs from a typical cloudier year to a typical sunnier year, based on 19 years of data.
Free · no sign-up

See what this means for your bill

Our estimator uses these same figures for your district and roof, and shows the month-by-month range.

Assumption registry

The figures behind every estimate

Every public number we use, with its source and the date we last checked it.

The figures behind every estimate
FigureValueUnitSourceVerified
Installed cost benchmark72000 INR/kWINR/kWOwner-confirmed on-grid installed cost with ALMM modules in Jharkhand (3 kW ≈ ₹2.1–2.2 lakh, 2026-09-27)2026-11-18
Hazaribagh generation, kWh per kW per dayConservative: 3.88 kWh/kW/day Spring peak: 4.39 kWh/kW/day Summer and monsoon: 3.05 kWh/kW/day Autumn: 4.16 kWh/kW/day Winter: 4.32 kWh/kW/day Annual average: 3.88 kWh/kW/daykWh/kW/dayPVGIS 5.3 (EC Joint Research Centre), PVGIS-ERA5, 2005–2023: 1 kWp at Hazaribagh, 14% system loss2026-11-18
Net-metering feasibility timeline7–21 daysdaysSolar Center operating experience (owner-confirmed 2026-09-23)2026-11-18
Net-metering fees up to 50 kWApplication fee: 250 INR Registration fee: 1000 INRINRJBVNL sub-division net-metering fee structure2026-11-18
Bidirectional meter installation timeline25–30 daysdaysSolar Center operating experience (owner-confirmed 2026-09-23)2026-11-18
Distribution transformer capacity ceiling15 percentagepercentageJBVNL Distribution Transformer 15% rated capacity ceiling rule2026-11-18
Rate for unadjusted banked solar energy0.5 INR/kWhINR/kWhJSERC notified rate for unadjusted banked solar energy credits2026-11-18
Roof area per kW60 sqft/kWsqft/kWStandard crystalline module rooftop footprint rule2026-11-18
Central subsidy cap78000 INRINRhttps://pmsuryaghar.gov.in — Hard cap at 3 kW for residential systems2026-11-18
Central subsidy for the first 2 kW30000 INR/kWINR/kWhttps://pmsuryaghar.gov.in2026-11-18
Central subsidy for the third kW18000 INRINRhttps://pmsuryaghar.gov.in2026-11-18
Subsidy disbursal timeline25–30 daysdaysSolar Center operating experience (owner-confirmed 2026-09-23)2026-11-18
JBVNL domestic tariff slabs0–200 units at 0 INR/kWh 200–400 units at 4.8 INR/kWh 400+ units at 6.85 INR/kWhINR/kWhBase rate: JSERC True-up FY23-24 & ARR/Tariff FY2025-26 Order (jserc.org/pdf/tariff_order/jbvnl-2025.pdf), Ch.12 p.258-259, applicable from 01.05.2025 — flat Rs 6.85/kWh urban, non-telescopic; corroborated by India TV/Daily Pioneer/Deccan Herald coverage of the same May-2025 hike. Khushhali 200/400-unit bands and the Rs 2.05/unit 201-400 subsidy: converging secondary sources (govtschemes.in, Times Now Hindi, tankcalculator.com) — no primary government order text confirmed. Replaces the prior four-slab telescoping table (Rs 3.25-7.50), which matched no current JSERC order.2026-11-18
JBVNL electricity duty0.05 ratioratioJSERC order confirms duty is levied separately under the state Electricity Duty Act (Ch.13 Cl.II) but does not itself state the %; 5% figure carried over from prior verification, not re-confirmed against the Duty Act this pass.2026-11-18
JBVNL domestic fixed charge100 INR/monthINR/monthJSERC True-up FY23-24 & ARR/Tariff FY2025-26 Order (jserc.org/pdf/tariff_order/jbvnl-2025.pdf), Ch.12 p.258-259, applicable from 01.05.2025 — urban rate (Rural: Rs 75/month, Urban: Rs 100/month). Solar Center defaults to urban, its documented primary segment (docs/01-jharkhand-market-brief.md).2026-11-18